High Voltage Surge Arresters - Buyer´s Guide
ID:1HSM954312-00en
,
REV:AH
English
132 pages Buyer's Guide: ABB surge arresters are the primary protection against atmospheric and switching overvoltages. They are generally connected in parallel with the equipment to be protected to divert the surge current. The active elements (ZnO blocks) of ABB surge arresters are manufactured using a highly non-linear ceramic resistor material, composed primarily of zinc oxide mixed with other metal oxides and sintered together. Strong focus on quality at all stages, from raw material through to finished product, ensures that ABB surge arresters survive the designed stresses with ease and with good margins. Different dimensions permit a large variety of standard arresters as well as client-specific solutions as regards protection levels and energy capability. This Buyer’s Guide deals with high voltage surge arresters for standard AC applications. For other applications, such as series capacitors protection, shunt capacitor protection or DC applications, contact your ABB sales representative. surge arresters in SF6 gas-insulated design for mounting on all commercial GIS switchgear.
Product guide
Product guide
2019-06-03
PUBLIC
Type PEXLIM Surge Arresters 72-362 kV
ID:2GNL010011
,
REV:A
English
Protection of high voltage system assets. Brochure for the North American market.
Brochure
Brochure
2018-09-26
PUBLIC
Silicone-housed surge arrester PEXLIM P-Z
ID:9AKK107045A9353
,
REV:A
English
Leaflet
Leaflet
2018-02-07
PUBLIC
Surge Arresters Buyer´s Guide - Section PEXLIM R-Y
ID:1HSM 9543 12-00en Section PEXLIM R-Y
,
REV:D
English
Product guide
Product guide
2017-05-04
PUBLIC
Surge Arresters Buyer´s Guide - Section PEXLIM Q-Y
ID:1HSM 9543 12-00en Section PEXLIM Q
,
REV:O
English
Product guide
Product guide
2017-05-04
PUBLIC
Surge Arresters Buyer´s Guide - Section PEXLIM P-Y
ID:1HSM 9543 12-00en Section PEXLIM P-Y
,
REV:F
English
Product guide
Product guide
2017-05-04
PUBLIC
Surge Arrester ZnO block testing
ID:1HSM954313-05en
,
REV:-
English
Leaflet
Leaflet
2015-04-17
PUBLIC
Insulation withstand and clearances with EXLIM and PEXLIM surge arresters
ID:1HSM954316-01en
,
REV:B
English
This technical information discusses the different aspects of insulation withstand and provides guidelines for positioning EXLIM and PEXLIM surge arresters in outdoor substations.
Technical description
Technical description
2015-01-20
PUBLIC
PDO, Petroleum Development of Oman, Silicone rubber insulators in air insulated substations
ID:1HSM954324-12
,
REV:-
English
Leaflet about successful installation and use high voltage apparatus with silicone rubber insulators
Reference case study
Reference case study
2013-06-27
PUBLIC
Physical properties of zinc oxide varistors
ID:PTHVP/A 2350en
,
REV:A
English
Technical description
Technical description
2013-02-15
PUBLIC
Annex to ISO 9001 & 14001 Certification for ABB High Voltage Products in Ludvika, Sweden
ID:9AKK105408A9618
,
REV:-
English
Certificate from BVQI valid until April 2015
Certificate
Certificate
2012-07-03
PUBLIC
High Voltage Surge Arresters - Buyer's Guide
ID:1HSM 9543 12-00fr
,
REV:D
French
108 pages Buyers Guide (french): ABB surge arresters are the primary protection against atmospheric and switching overvoltages. They are generally connected in parallel with the equipment to be protected to divert the surge current. The active elements (ZnO blocks) of ABB surge arresters are manufactured using a highly non-linear ceramic resistor material, composed primarily of zinc oxide mixed with other metal oxides and sintered together. Strong focus on quality at all stages, from raw material through to finished product, ensures that ABB surge arresters survive the designed stresses with ease and with good margins. Different dimensions permit a large variety of standard arresters as well as client-specific solutions as regards protection levels and energy capability. This Buyer’s Guide deals with high voltage surge arresters for standard AC applications. For other applications, such as series capacitors protection, shunt capacitor protection or DC applications, contact your ABB sales representative. surge arresters in SF6 gas-insulated design for mounting on all commercial GIS switchgear.
Product guide
Product guide
2011-10-04
PUBLIC
High Voltage Surge Arresters - Buyer´s Guide
ID:1HSM 954312-00ru
,
REV:-
Russian
108 pages Buyer's Guide (russian): ABB surge arresters are the primary protection against atmospheric and switching overvoltages. They are generally connected in parallel with the equipment to be protected to divert the surge current. The active elements (ZnO blocks) of ABB surge arresters are manufactured using a highly non-linear ceramic resistor material, composed primarily of zinc oxide mixed with other metal oxides and sintered together. Strong focus on quality at all stages, from raw material through to finished product, ensures that ABB surge arresters survive the designed stresses with ease and with good margins. Different dimensions permit a large variety of standard arresters as well as client-specific solutions as regards protection levels and energy capability. This Buyer’s Guide deals with high voltage surge arresters for standard AC applications. For other applications, such as series capacitors protection, shunt capacitor protection or DC applications, contact your ABB sales representative. surge arresters in SF6 gas-insulated design for mounting on all commercial GIS switchgear.
Product guide
Product guide
2010-02-01
PUBLIC
Short-circuit behaviour - Surge arresters and counters
ID:9AKK101130D7239
,
REV:-
Portuguese
Article
Article
2007-05-21
PUBLIC
Short-circuit behaviour - Surge arresters and counters
ID:9AKK101130D7156
,
REV:-
Russian
7 page article in Russian
Article
Article
2007-05-08
PUBLIC
Short-circuit behaviour - Surge arresters and counters
ID:9AKK101130D7155
,
REV:-
Spanish
7 page article
Article
Article
2007-05-08
PUBLIC
Short-circuit behaviour - Surge arresters and counters
ID:9AKK101130D7154
,
REV:-
English
7 page article
Article
Article
2007-05-08
PUBLIC
Design and testing of polymer-housed surge arresters with special emphasize on seismic stresses and selection of specific creepage in costal areas
ID:2005-09 Tokyo Cigre
,
REV:-
English
Results from pollution withstand tests on polymer-housed metal-oxide surge arresters are given. The results are used to calculate the risk for flashover of arrester insulators at different pollution levels and for different selection of creepage distance. The calculations are calibrated against long term field test results at two heavy polluted test sites in UK and South Africa. The outcome of the calculations indicates that it is possible to significantly decrease the required creepage for arresters in coastal areas with the use of polymer-housings with silicone rubber as external insulation. Paper presented at Cigre joint colloquium, Tokyo September 2005.
Article
Article
2005-11-03
PUBLIC
TOV & Protective Characteristics for Surge Arresters
ID:1HSM9543 13-01en
,
REV:E
English
Data sheet
Data sheet
2005-10-17
PUBLIC
TOV & Protective Characteristics for Surge Arresters - Section PEXLIM P
ID:1HSM9543 13-01en Section PEXLIM P
,
REV:C
English
Data sheet
Data sheet
2005-09-12
PUBLIC
Seismic test - high voltage surge arresters type PEXLIM
ID:seismic test
,
REV:-
English
A seismic test performed at Astro Nuclear/Dynamic Inc. (ANDI), Jefferson Hills, PA, USA. 1 g ground acceleration tested on multi-axis shaking table according to IEEE 693 draft 1 (1998). Test specimens: PEXLIM Q192-XH245 and PEXLIM Q060-XV072.
Movie
Movie
2005-05-18
PUBLIC
Production of high voltage surge arresters type PEXLIM
ID:pexlim
,
REV:-
English
Movie
Movie
2005-05-18
PUBLIC
Introduction to high voltage surge arresters manufactured by ABB
ID:Surgearresters
,
REV:-
English
Movie
Movie
2005-05-18
PUBLIC
Improved transmission line performance using polymer-housed surge arresters.
ID:2000-10 Manila Cepsi
,
REV:-
English
This paper discuss in greater detail the role of arresters in improving the reliability of supply over HV transmission lines, the desirable electrical and mechanical characteristics for such arresters and accessories and ABB's designs to obtain such characteristics using polymeric arresters without any external gaps. Paper presented at CEPSI seminar, Manila October 23-27, 2000.
Article
Article
2005-03-24
PUBLIC
Limitation of switching overvoltages by use of transmission line arresters.
ID:1998 Zagreb Cigre
,
REV:-
English
This report describes the use of transmission line arresters on EHV lines in order to limit switching surge overvoltages. Overvoltages profiles along sample lines are given for a number of installed arresters along the lines. In addition energy requirements on station and transmission line arresters are given. A polymer-housed arrester suitable for line switching surge control is presented. Paper presented at Cigré SC-33 international conference, Zagreb, 1998.
Article
Article
2005-03-24
PUBLIC
A compact 420 kV line utilising line surge arresters for areas with low isokeraunic levels
ID:1998 Paris Cigre 22 308a
,
REV:-
English
This report describes the work carried out to develop a delta 420 kV compact line with 5 m phase spacing, utilising line surge arresters and elimination shield wires. Long term audible noise meaurements were taken on a full-scale outdoors test line. Special grading rings were developed and tested. The design is based on tension towers only, to overcome the clearance problems of short insulator strings on compact towers. Paper presented at Cigré general session, Paris, 1998.
Article
Article
2005-03-24
PUBLIC
Design and testing of polymer-housed surge arresters.
ID:1998-10 Abu Dhabi Cigre
,
REV:-
English
Since some years, arresters with polymer-housings have been available on the market for distribution and medium voltage systems. In recent years, this type of arresters have been introduced also on higher voltage systems up to and including 550 kV. However, the international standardisation work is far behind this rapid development and many of existing designs with polymer-housings for high voltage systems have only been tested according to existing IEC standard, IEC 99-4 of 1991, which in general only covers arresters with porcelain housings. Paper presented at GCC Cigré 9th symposium, Abu Dhabi, October 28-29, 1998.
Article
Article
2005-03-24
PUBLIC
Energy stress on transmission line arresters considering the total lightning charge distribution
ID:1996-09 Los Angeles IEEE
,
REV:-
English
Tranmission line arresters may be subjected to high energy stresses caused by lightning. Calculations of energy stresses were carried out for a typical line arrester installation. Three line configurations with different degree of shielding efficiency were used for the study. The calculated results were compared with energy stresses in standardized tests on surge arresters. Paper presented at IEEE/PES transmission and distribution conference and exposition, Los Angeles, September 1996.
Article
Article
2005-03-24
PUBLIC
Selection, dimensioning and testing of line surge arresters
ID:1996-04 Rio de Janeiro Cigre
,
REV:-
English
Transmission line arresters may be subjected to high energy stresses caused by lightning. Calculation of energy stresses were carried out for a typical 138 kV line arrester installation. An additional type test procedure is proposed to account for energy stresses typical for line arresters with regard to lightning conditions. Paper presented at the Cigré Brazil SC-33 International workshop on line surge arresters and lightning, Rio de Janeiro, Brazil, April 24-26, 1996
Article
Article
2005-03-23
PUBLIC
Thermal behaviour of ZnO surge arresters in polluted conditions.
ID:1992 Paris Cigre
,
REV:-
English
The thermal performance of ZnO surge arresters were studied in the laboratory and in the field. Results from two natural pollution test sites are presented in terms of temperature rise and charge accumulation. The feasibility of reproducing the thermal stress on the arresters in the laboratory by means of the salt fog method and the slurry method is discussed. Paper presented at Cigré general session, Paris, 1992.
Article
Article
2005-03-23
PUBLIC
New method for measurement of the resistivive leakage currents of metal-oxide surge arresters in service.
ID:IEEE 89SM817-8 PWRD
,
REV:-
English
Various methods for determination of the condition of ZnO surge arresters by means of measurement of the arresters leakage current are discussed. A new method, which is based on harmonic analysis of the leakage current is presented. The report were Presented at IEEE SM, Long Beach, California, July 9-14, 1989
Article
Article
2005-03-23
PUBLIC
TOV & Protective Characteristics for Surge Arresters - Section PEXLIM R
ID:1HSM9543 13-01en Section PEXLIM R
,
REV:B
English
Data sheet
Data sheet
2004-11-01
PUBLIC
TOV & Protective Characteristics for Surge Arresters - Section PEXLIM Q
ID:1HSM9543 13-01en Section PEXLIM Q
,
REV:B
English
Data sheet
Data sheet
2004-11-01